Products & Solutions
- Flow Metering
-
Gas & Flame Detection, Environment Monitoring
- Colorimetric Gas Detector Tubes
- Environment Monitors
- Fixed Gas Detectors
- Flame Detectors
- Gas Analyzer
- Personal Gas Detectors
- Portable Gas Detectors
- Material Testing
- Remote Asset Monitoring
- Specialty Applications
Select Application
Select Category
Gas Analyzer
- Colorimetric Gas Detector Tubes
- Environment Monitors
- Fixed Gas Detectors
- Flame Detectors
- Gas Analyzer
- Personal Gas Detectors
- Portable Gas Detectors
Gas Analyzer
Mini Sentry Series Single Gas UVDOAS Analyzers
The Mini Sentry series Single Gas analyzers are engineered specifically for low cost, low maintenance, high performance point or optional open path monitoring. The Mini Sentry’s compact size allows for a wide variety of mounting options for your custom solution. In addition, the Mini Sentry has multiple optional outputs to allow integration into your existing alarm or 4-20mA systems.
The Mini Sentry is available in versions for monitoring of Benzene, Ammonia and Chlorine respectively.
Features
- Automated data reporting and alarms
- 5 Year Service Interval
- WiFi / Ethernet Ready
- NEMA 4 Enclosure
Point Monitor or Open Path Analyzer
Specifications
Dynamic Range | Alarm (pre-configured) | Alarm (user configurable) | Power | Bulb Life | Dimensions | Sample Rate | Data Output | |
Mini Sentry Benzene, C6H6 | 275 PPB to 2500 PPM as Point Analyzer | 1 PPM (OSHA PEL TWA) 5 PPM (OSHA STEL) 500 PPM (NIOSH IDLH) | Concentration & Average concentration alarm functionality | 120 VAC, 100W (DC Optional) | 5 year replacement interval | 16 x 16.9 x 12.3 (in) Enclosure NEMA 4X | 220.6 CFM | .CSV via VNC, Email Optional: RS‐232, RF Stream, 4‐20mA or 0‐5VDC Analog via 16 Bit DAC |
Mini Sentry Ammonia, NH3 | 2.5 PPM to 25% Auto‐Ranging | 25 PPM (NIOSH REL TWA and ACGIH TLV TWA) 35 PPM (NIOSH and ACGIH STEL) 50 PPM (OSHA PEL TWA) 300 PPM (NIOSH IDLH) | Concentration & Average concentration alarm functionality | 120 VAC, 100W (DC Optional) | 5 year replacement interval | 16 x 16.9 x 12.3 (in) Enclosure NEMA 4X | 220.6 CFM | .CSV via VNC, Email Optional: RS‐232, RF Stream, 4‐20mA or 0‐5VDC Analog via 16 Bit DAC |
Mini Sentry Chlorine, Cl2 | 0.125 PPM to 50,000 PPM Auto‐Ranging | 0.5PPM (NIOSH REL TWA and ACGIH TLV TWA) 10 PPM (NIOSH IDLH) | Concentration & Average concentration alarm functionality | 120 VAC, 100W (DC Optional) | 5 year replacement interval | 16 x 16.9 x 12.3 (in) Enclosure NEMA 4X | 220.6 CFM | .CSV via VNC, Email Optional: RS‐232, RF Stream, 4‐20mA or 0‐5VDC Analog via 16 Bit DAC |